  资源消耗问题一直困扰着许多行业的发展,空气净化工程行业也不例外。面对《中国制造2025》中强调的能源消耗,制造商必须考虑节能的重要性。近年来,洁净室的能源消耗引起了人们的广泛关注。
  The problem of resource consumption has been plaguing the development of many industries, and the air purification engineering industry is no exception. Facing the energy consumption emphasized in Made in China 2025, manufacturers must consider the importance of energy saving. In recent years, the energy consumption of clean rooms has attracted wide attention. What are the main reasons for the high energy consumption in the clean room purification process? What energy-saving measures should be taken? Next, let's introduce the air purification project.
  空气净化工程能耗大的主要原因:一般空调有的只具有一级过滤效果,要求较高的是一级过滤效果,二级过滤的中间效果。净化空调需要三级过滤,即一级、中级、高效三级过滤,或一级、中级、次高效三级过滤。随着每一阶段的过滤,空气更干净,但它也增加了过滤的成本。一般中央空调系统平均换气次数只有10次/小时以下,而净化空调系统需要超过12次/小时,甚至是一般中央空调系统换气次数的10倍以上。因此,净化空调系统每平方米的能耗是普通中央空调系统的10 ~ 20倍。
  The main reason of high energy consumption in air purification project is that some air conditioners only have one-stage filtering effect, and the higher requirement is the first-stage filtering effect and the intermediate effect of the second-stage filtering. Purification air conditioning requires three-stage filtration, i.e. one-stage, intermediate and high-efficiency three-stage filtration, or one-stage, intermediate and sub-high-efficiency three-stage filtration. With each stage of filtration, the air is cleaner, but it also increases the cost of filtration. In general, the average ventilation times of central air-conditioning system are less than 10 times per hour, while the purification air-conditioning system needs more than 12 times per hour, even more than 10 times of the ventilation times of general central air-conditioning system. Therefore, the energy consumption per square meter of the purified air conditioning system is 10 to 20 times that of the ordinary central air conditioning system.
  洁净室的节能措施:自恒温中需要净化手术室,在手术室净化空调系统应配备独立的冷热源,以避免恒温在洁净室的中央空调医院服务的过度季节。二次回风系统通过设定一次回风率和二次回风率来消除再热,既消除了再热功耗,又通过调节一次回风率和二次回风率来降低仪表冷却器的冷却负荷。回收热源后,冷却机冷凝的热量初是排放到大气中的余热,通过回收利用可以很好地再热源。许多企业的洁净室采用空冷机,通过改造热回收周期即可安装,比电加热和锅炉热水更经济。
  Energy-saving measures of clean room: It is necessary to purify the operating room from constant temperature, and the air-conditioning system of clean room should be equipped with independent cold and heat sources to avoid the excessive season of constant temperature in the central air-conditioning Hospital of clean room. Secondary return air system eliminates reheating by setting primary return air rate and secondary return air rate. It eliminates reheating power consumption and reduces cooling load of instrument cooler by adjusting primary return air rate and secondary return air rate. After the heat source is recovered, the heat of the condenser is the waste heat discharged into the atmosphere at first, which can be well re-heated by recycling. Many clean rooms in enterprises adopt air coolers, which can be installed by reforming the heat recovery cycle, which is more economical than electric heating and boiler hot water.
  根据小边的要求,洁净室的净化参数应根据企业的实际生产需求进行设置,净化空调系统的设置应科学合理,以降低空气净化工程的大能耗。
  According to the requirement of small side, the cleaning parameters of clean room should be set according to the actual production demand of enterprises, and the setting of cleaning air conditioning system should be scientific and reasonable to reduce the large energy consumption of air purification project.